Cut Specimen Shear [part# 980104-11]
Uniform specimen size is critical for repeatable and reproducible
test results. The TABER® Triple Cut Specimen Shear
will prepare consistent specimens for most materials up to 0.020"
in thickness. The standard specimen size is 1 1/2" x 2 3/4". For test ranges 1 or 2, specimens must be rotated 90 degrees and cut a second time to obtain the required 1 1/2" x 1 1/2" sample size.
Ratchet
Stop Roller
[part# 130240]
Now standard on all models of TABER Stiffness Testers, the Ratchet
Stop Roller greatly reduces the potential for inter-operator error
caused by over or under-tightening.
The travel on the right hand assembly automatically stops when the
roller contacts the specimen. This allows the operator to precisely
set the distance between the specimen and roller, which results
in improved test set-up.
This accessory can be retrofitted on any TABER Stiffness Tester.
Sensitivity
Range Attachment
[part# 980150-14]
The Sensitivity Range Attachment (also referred to as SR or High
Sensitivity Attachment) is used to test the stiffness of extremely
lightweight materials including cellophane, natural fibers, synthetic
filaments, metallic foils, and more.
A 1 ½" x 1 ½" specimen is mounted between
a set of pin holders, which replace the rollers. Use of this attachment
requires the Compensator Range Weight.

Wire
/ Tube Testing Apparatus [part# 131030]
Designed to test cylindrical specimen materials, this accessory
securely holds samples up to 4mm in diameter without any deformation.
Each apparatus includes a top and bottom gauge block, which is customized
to the diameter of your specimen.
Range
Weights
To
test specimens below 10 stiffness units, the Compensator Range Weight
is required. Specimens above 100 stiffness units require additional
range weights as determined by the test set-up chart.
- Replacement
Compensator Range Weight - 10 Taber Units [part#
120815]
- Replacement
Range Weight - 500 Taber Units [part# 120753]
- Replacement
Range Weight - 1000 Taber Units [part# 120752]
- Replacement
Range Weight - 2000 Taber Units [part# 120751]
- Auxiliary
Range Weight Set - range 3000 - 5000 Taber Units [part#
125656]
- Case
for Range Weights [part# 120888]
Calibration
Specimens
To confirm the proper operation of your Stiffness Tester, TABER
offers five spring steel calibration specimens. Each specimen is
electro-etched with the exact rating before leaving the factory.
- Calibration
Specimen 62 [part# 125390-1]
- Calibration
Specimen 225 [part# 125390-2]
- Calibration
Specimen 440 [part# 125390-3]
- Calibration
Specimen 565 [part# 125390-4]
- Calibration
Specimen 1060 [part# 125390-5]
6mm
Clamp Jaw Upgrade [part# 1125762]
Increase the specimen thickness of older model Stiffness Testers
with an upgrade to the 6mm Clamp Jaws. These jaws allow you to increase
specimen thickness from a maximum 0.125" to 0.219", and
are standard on all current models.
Step-Down
Transformer (220/110V) [part# 112954]
The Step-Down Transformer is required to operate the TABER Stiffness