Maintenance Tips:

 

Taber Reciprocating Abraser

  • The linear slide and pivot block bearings are factory lubricated and should not require regular lubrication.
  • If debris from testing collects on the linear slide, gently wipe it with a clean cloth. Do NOT remove the bearings from the slide.  A light grease such as #2 white lithium may be used to lubricate the slide.
  • When using the lock mechanism, remove all weights from the tool / weight holder.  Should the angle of the lock mechanism need to be adjusted, loosen the screws that secure the horizontal post into the clamp connectors using the 5mm hex-L key.  Carefully rotate the horizontal post until the desired angle is achieved and tighten the clamp connector set screws.